Home IOLS Medicontur Bi-Flex ELON
Medicontur ELON Wavefront Linking

Medicontur

Bi-Flex ELON

ELONgated Depth of Focus

 Wavefront Linking Technology
EDoF IOL
Preloaded injector

Medicontur Bi-Flex ELON

To create minimal optical disturbances, Medicontur invented Wavefront Linking, a non-diffractive technology for a wide range of vision. This proprietary technology is based on a series of central concentric refractive zones varying in curvature and linked by specially designed linking zones.

Wavefront Linking enables light energy to be distributed continuously along the optical axis. Connected focal points result in a singular ELONgated focus, useful across the entire range of vision. With no diffractive rings, Wavefront Linking technology lowers the risk of visual disturbances compared to diffractive EDoF solutions on the market.

[WPSM_AC id=4503]

[WPSM_AC id=4504]

Non-diffractive Extended Depth of Focus (EDoF) IOLs.  The latest generation of presbyopia-correcting IOLs.

Using several physical or optical principles, ELON IOL aims to satisfy the visual needs of patients who lead an active lifestyle, while minimising the risk of dysphotopsia compared to diffractive technologies.

877PEY preloaded injector system

EDoF single piece, sterile, foldable aspheric hydrophobic acrylic IOL with UV blocker and blue light filter.

Download
Technical specifications
Description & Technical Specs

Medicontur Bi-Flex ELON

877PEY

Single piece, sterile, foldable aspheric hydrophobic acrylic intraocular lens (IOL) with UV blocker and blue light filter. The optic is EDOF. The IOL is available as part of a preloaded injector system.

Power range

Standard: +8.0 D → +30.0 D (0.5 D steps)

Extreme: +31.0 D → +35.0 D (1.0 D steps)

Hydrophobic acrylic with UV blocker and blue light filter

Refractive Index: 1.47

Abbe Number: 58

Design

Optic Diameter: 6mm

Overall Diameter: 13mm

Optic Design: Aspheric – Aberration Neutral Biconvex (+8.0 D → +35.0 D)

Nominal A-constant: 118.9

EDOF Zone: Refraction-based central Wavefront Linking zones

Haptic Design: Posterior vaulting fenestrated C-loops with 0° angulation

PCO Prevention: 360° sharp edge

Shelf Life: 2.5 years after sterilisation

Injection

Estimated Incision Size: 2.2mm

Compatible injector: POB-MA single use | Pre-loaded injector

Constants

SRK/T A-Constant: A = 118.9

Haigis: a0 = 1.32 | a1 = 0.4 | a2 = 0.1

Hoffer Q: pACD = 5.46

Holladay I: SF = 1.7

Barrett Universal II: LF = 1.83

Holladay II: ACD = 5.49 | SF = 1.73

 

[WPSM_AC id=4505]